DIN Series

DIN Series Panel Meters Provide Maximum Flexibility

RT Engineering's DIN Series panel meters provide maximum flexibility in the field of digital indication. The DIN series combines a Universal input scheme with a product so Versatile, it can be used in a wide variety of applications - one model that's capable of doing many things well.

DIN Series digital panel meter

Voltage Input Models accept AC or DC inputs from 50 MV to 500 V from a multitude of signal sources. The DIN Series meters can monitor and display electrical units, such as AC or DC amps and volts, or other engineering units, such as FPM, RPM, GPM and others.

Accuracy, Reliability, and Versatility backed by a two-year warranty

Specifications

Voltage Model Specifications
Typical Input Signals:
AC or DC signals from motor armatures, line or reference voltages, tachometers, force transducers (load cells), shunts, current transformers, pressure and flow transducers
Input Ranges:
(A) 50mvDC; 100mvAC (B) 500mvDC; 1VAC (C) 5VDC; 10VAC (D) 50VDC; 100VAC.
Note:
"D" scale accepts voltages up to 500VDC/480VDC
Maximum Input and Overrange:
1000‰ of range or 500V AC and DC which ever is less
Input Resistance at Nominal Scale Values:
20K Ohms/volt, AC and DC
AC Frequency Range:
Max. signal: 500 Hz, Min. signal: 40 Hz
Accuracy:
.5‰ linear +/- 1 digit full scale
Sampling Time:
.4 seconds/reading update
Response Time (0 to full scale):
5 seconds
Power Requirement:
115VAC (+/- 10V), 50/60 Hz, 2 watts
Operating Temperature:
5°C to 50°C
Calibration Method:
Scale selecting jumper and a 20-turn potentiometer for coarse adjustment and a multi-turn potentiometer for fine tuning
Construction:
RFI shielded high impact (UL94V-0) plastic case with LOX-IT self locking Lexan bezel over display
Weight:
1 pound
Process Control Model Specifications
Typical Input Signals:
Current source, typically 4-20MA, 5-50MA, or offset voltage 1-5VDC, etc.
"BIAS" Adjustment Range:
0-40‰ of full scale
"SCALE" Adjustment Range:
10-100‰ of full scale
Shunt Resistance:
Infinite or 250 ohms customer jumper selectable (other values of 50 to 600 ohms inclusive are available on customer request)
Accuracy:
.5 linear +/- 1 digit full scale
Sampling Time:
.4 seconds/reading update
Response Time (0 to full scale):
5 seconds
Power Requirement:
115VAC (+/- 10V), 50/60 Hz, 2 watts
Operating Temperature:
5°C to 50°C
Construction:
RFI shielded high impact (UL94V-0) plastic case with LOX-IT self locking Lexan bezel over display
Weight:
1 pound
Pulse Model Specifications
Typical Input Signals:
Standard magnetic pickup (30 inches per sec. minimum gear or sprocket speed at 1/64" maximum gap) Hall effect type pickup which can operate from the 5VDC meter supply or slow speed type pickup such as RT Engineering P/N RT-58426. A 1/32" maximum gap is required between the gear and pickup. Output wave-form from either six step, pulse width modulated (PWM), or current source inverter up to 480VAC when the meter has proper interface. Signal isolation transformer P/N RT-TA-181210 is available if customer required.
Standard Input Signal Range:
5PPS to 22,000PPS
Accuracy:
.5‰ linear +/- 1 digit full scale
Sample Time:
.4 seconds/reading update
Response Time (0 to full scale):
5 seconds
Power Requirement:
115VAC (+/- 10V), 50/60 Hz, 2 watts
Operating Temperature:
5°C to 50°C
Calibration Method:
Scale selecting jumper and a 20-turn potentiometer for coarse adjustment and a multi-turn potentiometer for fine tuning
Construction:
RFI shielded high impact (UL94V-0) plastic case with LOX-IT self locking Lexan bezel over display
Weight:
1 pound

Dimensions

DIN series 1 - digital panel meter

Manuals