DPM Series

The Two-Minute Analog-To-Digital Meter Retrofit

Upgrade error-prone analog meters quickly with highly accurate, solid state Universatile digital indicators from RT Engineering.

DPM Panel Meters

The physical mounting dimensions of the DPM Series match most existing analog meters, eliminating the need to recut and redrill existing panels.

Capable of accepting AC or DC input signals from 50 mV to 500 V, one model can display Amps, Volts, RPM, GPM, FPM or other rate related engineering units of measurement. Accuracy, Reliability and Versatility backed by a two-year warranty.

Specifications

Voltage Model Specifications
Typical Input Signals:
AC or DC signals from motor armatures, line or reference voltages, tachometers, force transducers (load cells), shunts, current transformers, pressure and flow transducers
Input Ranges:
(A) 50mvDC; 100mvAC (B) 5VDC; 10VAC (C) 50VDC; 100VAC (D) 500VDC; 480VAC
Input Resistance at Nominal Scale Values:
20K Ohms/volt DC 9K Ohms/volt AC
AC Frequency Range:
Max. signal: 2K Hz, Min. signal: 40 Hz
Accuracy:
.5‰ linear +/- 1 digit full scale
Sampling Time:
.33 seconds/reading update
Response Time (0 to full scale):
6.5 seconds
Power Requirement:
115VAC (+/- 10V), 50/60 Hz, 2 watts
Operating Temperature:
5°C to 50°C
Calibration Method:
Scale selecting jumper and a 25-turn potentiometer
Construction:
18 gauge steel with Lexan bezel over display
Weight:
1 pound
Process Control Model Specifications
Typical Input Signals:
Current source, typically 4-20MA, 5-50MA, or offset voltage 1-5VDC, etc.
"BIAS" Adjustment Range:
0-50‰ to full scale
"SCALE" Adjustment Range:
0-100‰ of full scale
Shunt Resistance:
250 ohms provided standard
Accuracy:
.5 linear +/- 1 digit full scale
Sampling Time:
.33 seconds/reading update
Response Time (0 to full scale):
6.5 seconds
Power Requirement:
115VAC (+/- 10V), 50/60 Hz, 2 watts
Operating Temperature:
5°C to 50°C
Construction:
18 gauge steel with Lexan bezel over display
Weight:
1 pound
Pulse Model Specifications
Typical Input Signals:
Standard magnetic pickup (30 inches per sec. minimum gear or sprocket speed at 1/64" maximum gap) Hall effect type pickup which can operate from the 5VDC meter supply or slow speed type pickup such as RT Engineering P/N RT-58426. A 1/32" maximum gap is required between the gear and pickup. Output wave-form from either six step, pulse width modulated (PWM), or current source inverter up to 480VAC when the meter has proper interface. Signal isolation transformer P/N RT-TA-181210 is available if customer required.
Standard Input Signal Range:
5PPS to 22,000PPS
Accuracy:
1‰ linear +/- 1 digit full scale
Sample Time:
.33 seconds/reading update
Response Time (0 to full scale):
6.5 seconds
Power Requirement:
115VAC (+/- 10V), 50/60 Hz, 2 watts
Operating Temperature:
5°C to 50°C
Calibration Method:
Range selecting capacitor and 25-turn potentiometer
Construction:
18 gauge steel with Lexan bezel over display
Weight:
1 pound

Dimensions

DPM series junior DPM series - standard